Aeroglaze® A276 coating is a reflective, moisture-curing polyurethane coating designed for product finishing applications on substrates used in aircraft and aerospace applications. Aeroglaze® A276 coating cures to a high gloss white finish.
Unit of Measure
Approvals and Conformities
|
Typical Properties
|
Specifications
|
Features
|
Directions for Use
|
Precautions for Use and Storage
|
Limitations
Approvals and Conformities
Approvals and Conformities |
N/A
Ball Aerospace and Technologies - BMS29.98 Boeing - 52841092, 9M03235/AttachA, BMS10-90, D290-75502-22C, MB0125-080, SCGMS56016, STM0724 Cincinatti Electronics - 635907-1 Cytec Solvey - LMS 11953 Honeywell - P8251333 ILC Dover - ST41P1218 ITT, Space Systems - 561454 Lockheed Martin - LAC-37-4462-002, MAP-CK10787-1000, STM40601 Northrop Grumman - 53825TW Raytheon - HMS15-2135 Rockwell Collins - KB0125005 |
Typical Properties
Appearance |
N/A White Liquid |
Viscosity at 25 Degree Celsius (ºC) (77 Degree Fahrenheit (ºF)) Temperature1 | N/A 100 to 400 cP |
Test Method for Viscosity |
N/A American Society for Testing and Materials (ASTM D 2196-66) |
Density |
N/A 1.12 to 1.17 kg/L9.37 to 9.77 lb/gal |
Test Method for Density |
N/A American Society for Testing and Materials (ASTM D 1475-85) |
Solids Content by Weight |
N/A 54 to 578 % |
Test Method for Solids Content (Modified) |
N/A American Society for Testing and Materials (ASTM D 2369-87) |
Flash Point (Seta) Closed Cup Temperature |
N/A 19 ºC67 ºF |
Test Method for Flash Point (Seta) Closed Cup Temperature |
N/A American Society for Testing and Materials (ASTM D 3278-82) |
Volatile Organic Compounds (VOC) Volume |
N/A 503 g/L4.2 lb/gal |
Test Method for Volatile Organic Compounds (VOC) |
N/A American Society for Testing and Materials (ASTM D 3960-87) |
Outgassing Total Mass Loss (TML)2 | N/A 0.99 % |
Outgassing Collected Volatile Condensable Materials (CVCM)3 | N/A 0.08 % |
Solar Absorptivity Gier-Dunkle Integrating Sphere |
N/A 0.23 |
Specifications
Note for Typical Properties |
N/A Data is typical and not to be used for specification purposes. |
Features
Features and Benefits |
N/A
|
Directions for Use
Surface Preparation |
N/A Thoroughly clean surfaces to remove all dust, oil and grease. For most substrates, apply primer to ensure proper adhesion and performance of the coating. Contact your Socomore representative for recommended Aeroglaze® primer required for your application. |
Applications |
N/A
Apply coating by spray methods, or by brush to small areas. Aeroglaze® A276 coating is best applied at 13-35 ºC(55-95 ºF), with substrate temperatures at least 2.8 ºC (5 ºF) above the dew point.
|
Curing |
N/A
Aeroglaze® A276 coating cures by reacting with moisture in the air. Cure rate is dependent on the temperature, relative humidity and amount of air circulation needed to remove the solvent. Under the acceptable curing conditions, the coating will develop its ultimate properties in approximately 14 days. Lower temperatures and humidities will retard cure, while higher temperatures and humidities may cause bubbling. Aeroglaze® A276 coating may be recoated after the first application within 4 hours minimum and 24 hours maximum. Recoat time is dependent on temperature and humidity. High temperature and humidity promote fast cure while low temperature and humidity slow down the cure. In high temperature and high humidity conditions, recoat within 8 hours to prevent intercoat adhesion failure. If the maximum recoat time is exceeded, the surface must be roughened by sanding with fine sandpaper before recoating. |
Cleanup |
N/A Use Aeroglaze® 9958 thinner to clean equipment. Do not use lacquer thinners, water or solvents containing alcohols. |
Precautions for Use and Storage
Precautions for Use and Storage |
N/A
Shelf life is one year from date of shipment when stored in original, unopened container. Store indoors away from heat, sparks and open flames. To maintain product freshness, keep container closed when not in use and nitrogen purge after opening if possible. Before using this or any Socomore product, refer to the Safety Data Sheet (SDS) and label for safe use and handling instructions. For industrial/commercial use only. Must be applied by trained personnel only. Not to be used in household applications. Not for consumer use. |
- 1 Brookfield LVT
-
2 15 day cure at room temperature, 24 hours at 50 ºC (122 ºF).
Total Mass Loss -
3 15 day cure at room temperature, 24 hours at 50 ºC (122 ºF).
Collected Volatile Condensable Materials